Low Power Verification · All levels
Detecting Unintended State Loss Scenarios: Worked Example
Worked Example for Detecting Unintended State Loss Scenarios.
Worked example
Worked Example for Detecting Unintended State Loss Scenarios is anchored on Escaped state-loss incident rate per power mode and observability coverage of non-retained critical state.. Convert observations into mechanism-backed and owner-bound actions.
A regression appears in Escaped state-loss incident rate per power mode and observability coverage of non-retained critical state.. Strong closure isolates first failing boundary, proves mechanism, applies one reversible fix, and validates blast radius before release.
Execution lens
LOW-POWER VERIFICATION FLOW - Detecting Unintended State Loss Scenarios
power intent and mode definitions
|
v
domain controls and transition sequencing
|
v
simulation behavior (isolation, retention, corruption)
|
v
assertions and coverage evidence
|
v
triage, bounded fix, and signoff closureDecision matrix
EVIDENCE MATRIX - Detecting Unintended State Loss Scenarios
+-----------------------------+--------------------------------+--------------------------------+---------------------------+
| Evidence | Tells you | Does not prove | Next action |
+-----------------------------+--------------------------------+--------------------------------+---------------------------+
| transition timeline traces | first failing LP phase | complete root-cause ownership | correlate with intent map |
| UPF-aware assertion logs | contract violations by phase | silicon product impact | map to scenario severity |
| corruption/X classification | actionable vs noisy failures | legal transition completeness | replay key mode corners |
| save/restore snapshots | state integrity movement | isolation correctness | pair with crossing checks |
| before-after regressions | mitigation movement quality | long-tail stability | run full matrix |
+-----------------------------+--------------------------------+--------------------------------+---------------------------+Low-power verification deep dive
Retention closure requires proving end-to-end state lifecycle through save, off, and restore windows.
Concept diagram
RETENTION LIFECYCLE
save request -> state capture -> power off -> power on -> restore -> traffic resumeMetric graph
RETENTION STABILITY
restore mismatch █████
save timing defects ████
stable wake cycles ███████Metrics and artifacts to collect
retention save/restore timing report
pre/post state diff matrix
multi-cycle retention stress summary
state-loss bug trend by mode
Mini case study
A corruption issue persisted until retention checks compared multi-cycle state snapshots rather than single wake events.
Debug branches
Track save acknowledgement against actual state capture.
Validate restore completion before functional traffic resumes.
Run repeated sleep/wake cycles to expose drift.
Senior review question
Ask: what exact low-power transition boundary failed first, and which artifact proves the closure claim reproducibly?
Key takeaways
Tie each LPV claim to a concrete transition boundary and one proving artifact.
Prefer minimal reversible fixes with explicit owner and rollback criteria.
Common pitfalls
Treating power-aware failures as random before boundary classification.
Waiving X-prop failures before proving impact and root cause.
Declaring closure without deterministic replay across key modes.
Worked-example reasoning
Start by proving phase and boundary assumptions before tuning checks.
Use one reversible change per hypothesis to preserve causality.