STA Mastery · All levels
Signoff vs Implementation Views: Worked Example
Worked Example for Signoff vs Implementation Views.
Worked example
Worked Example for Signoff vs Implementation Views focuses on view delta WNS, parasitic corner mismatch, SPEF vs signoff RC gap. The goal is to connect the observable symptom to timing mechanism, ownership, and regression risk.
A signoff run shows view delta WNS, parasitic corner mismatch, SPEF vs signoff RC gap. The first review mistake is to blame implementation without checking constraints. A better review starts by pinning one critical path, proving where slack was lost, and checking whether the SDC rule is correct for Signoff vs Implementation Views.
Sequence under inspection
TIMING PATH — Signoff vs Implementation Views
launch FF --logic stages--> capture FF
| |
launch clock capture clock
| |
required: arrival < capture_edge - setup
metric: view delta WNS, parasitic corner mismatch, SPEF vs signoff RC gapView comparison
SAME NETLIST — TWO VIEWS
impl_view SPEF (typical) WNS = +50ps
signoff_view SPEF (cworst) WNS = -30ps
Delta is expected; panic only if delta exceeds historical bound.Capture report_timing and the relevant SDC excerpt.
Tag corner, mode, view, and path group.
Find the first cell or net that dominates critical delay.
Compare against view comparison report, SPEF tag manifest, delta slack log.
Choose one reversible ECO and write the regression matrix before editing netlist or constraints.
Did the fix work?
BEFORE / AFTER ECO — Signoff vs Implementation Views
WNS (ps)
0 | --- target
-50 | ● regressed
-80 | ● before ECO
-20 | ● after ECO
+-------------------------------> ECO iteration
Prove setup AND hold moved safely.STA deep dive
Signoff WNS is the minimum across the full scenario matrix.
Concept diagram
MMMC
corners (ss/tt/ff) x modes (func/test) x views (signoff RC)
= scenario set -> min(WNS) is signoffMetric graph
WNS HEATMAP BY CORNER
ss tt ff
setup -80 +10 +5
hold -15 -2 -8Reports and artifacts
per-corner WNS
mode summary
lib map audit
view delta
Mini case study
Passed TT typical but failed SS hold — signoff matrix was incomplete; added low-voltage mode.
Debug branches
Isolate failing scenario first
Never compare unlike SPEF tags
Senior review question
Ask: what corner/mode/view proves this topic is closed or failing?
Key takeaways
State corner, mode, view, and database tag with every slack claim.
Run setup and hold plus MMMC regression after every ECO.
Common pitfalls
Comparing STA runs with different SPEF or SDC tags.
Broad false_path to green-wash violations.
Setup-only ECO without hold check.
Principal STA review addendum
Implementation and signoff use different parasitic corners and analysis views; comparing them without mapping causes false panic or false confidence.
Metric: view delta WNS, parasitic corner mismatch, SPEF vs signoff RC gap