Setup / Hold Closure Order: Expanded Case Study

Expanded Case Study for Setup / Hold Closure Order.

Extended case study

Signoff review: setup WNS, hold WNS, simultaneous violation count fails after an apparently minor change affecting Setup / Hold Closure Order.

Background

Team had closure last week on full MMMC matrix. New run shows regression clustered in one path group.

Symptoms observed

  • setup WNS, hold WNS, simultaneous violation count regression

  • Disagreement between synth and STA WNS

  • Hold violations after setup ECO

Investigation timeline

  1. Hour 0: freeze netlist, SDC, SPEF, lib tags

  2. Hour 1: diff constraints and run manifest

  3. Hour 2: isolate corner/mode that fails

  4. Hour 3: read worst path — cell vs net, clocks

  5. Hour 4: classify root cause

  6. Hour 5: minimal ECO or SDC fix

  7. Hour 6: full regression + signoff memo

Root cause

Setup sizing ECO fixed WNS but created hold violations on short paths — regression caught on min analysis.

Fix and validation

  • Bounded ECO or audited SDC change

  • Re-run setup/hold trend chart, ECO sequence log, path replay

  • Full MMMC + SI regression

Lessons learned

  • Tag every run

  • Diff constraints before blaming PD

  • Setup and hold together

diagram
CASE STUDY — Setup / Hold Closure Order
baseline WNS / regressed WNS / post-fix WNS

Sequence under stress

diagram
TIMING PATH — Setup / Hold Closure Order

launch FF --logic stages--> capture FF
     |                           |
  launch clock                capture clock
     |                           |
  required: arrival < capture_edge - setup
  metric: setup WNS, hold WNS, simultaneous violation count

STA deep dive

ECO without regression is a coin flip.

Concept diagram

diagram
ECO LOOP

failing path -> fix -> setup check -> hold check -> SI -> MMMC matrix

Metric graph

diagram
ECO PROGRESS

WNS
 0 |              o target
-50|        o
-100|   o baseline
    +-----------------> ECO #

Reports and artifacts

  • pre/post WNS

  • hold delta

  • leakage delta

  • ECO ticket log

Mini case study

48-hour tapeout crunch: VT swap fixed setup; hold fixed with route on short path — order mattered.

Debug branches

  • Never ship setup-only proof

  • Logical ECO needs equivalence

Senior review question

Ask: what corner/mode/view proves this topic is closed or failing?

Key takeaways

  • State corner, mode, view, and database tag with every slack claim.

  • Run setup and hold plus MMMC regression after every ECO.

Common pitfalls

  • Comparing STA runs with different SPEF or SDC tags.

  • Broad false_path to green-wash violations.

  • Setup-only ECO without hold check.

Principal STA review addendum

Setup and hold compete through delay changes; closure order and ECO type must avoid fixing one at the expense of the other.

Metric: setup WNS, hold WNS, simultaneous violation count