DFT / ATPG · All levels

Shift vs Capture Timing: Debug Playbook

Debug Playbook for Shift vs Capture Timing.

Debug playbook

Debug Playbook for Shift vs Capture Timing focuses on shift hold violations, capture setup failures, at-speed pattern pass rate. The goal is to convert metric movement into mechanism, owner, and release decision.

Debug aims to find the first incorrect assumption, not the loudest downstream symptom. Start with reproducibility and ownership.

Root-cause tree

diagram
ROOT-CAUSE TREE - Shift vs Capture Timing

shift hold violations, capture setup failures, at-speed pattern pass rate regresses
        |
  setup changed?
    /        \
  yes         no
  |            |
constraint    silicon or
or ATPG       physical/test path
 /    \          |
SDC   model    chain/clock/power/diagnosis
diff  diff     isolate first failing signature
  1. Freeze run tags for patterns, constraints, and tester setup.

  2. Isolate first failing metric bucket and scenario.

  3. Classify failure source: model, constraints, physical, or silicon.

  4. Prove mechanism with one reduced replay or targeted run.

  5. Apply smallest owner-controlled fix.

  6. Re-run timing, power, and quality regression matrix.

Review memo template

diagram
STAFF DFT REVIEW MEMO - Test Timing & Power / Shift vs Capture Timing

1. Symptom
   - Watched metric: shift hold violations, capture setup failures, at-speed pattern pass rate
   - Failing scenario: <mode/lot/corner/program>
   - Pattern class: <scan/transition/compressed/BIST/JTAG>
   - Tags: <constraints, patterns, tester program, netlist>

2. Mechanism hypothesis
   - Primary mechanism: Shift mode is hold-sensitive while capture mode is setup-sensitive; closure must preserve both under test clocking assumptions.
   - Competing hypothesis: <constraint issue, model issue, physical issue, silicon issue>
   - Missing evidence: <report, replay, diagnosis trace>

3. Proposed action
   - Minimal reversible change: <constraint fix, architecture tweak, pattern update>
   - Expected metric movement: <delta>
   - Regression risk: timing, power, quality, schedule

4. Signoff
   - Re-run artifact: shift/capture timing report, at-speed validation logs, path-group summary
   - Required owners: STA owner, DFT owner, PD owner
   - Final decision: release, waive, rollback, or escalate

DFT deep dive

Test signoff fails when shift/capture timing and test power are treated independently.

Concept diagram

diagram
TEST SIGNOFF LOOP

test SDC -> shift/capture timing -> power-aware ATPG -> IR validation -> release

Metric graph

diagram
TEST CURRENT

functional current  baseline
scan shift current  peak-risk zone

Reports and artifacts

  • test-mode STA report

  • shift/capture split

  • test power IR map

  • waiver tracker

Mini case study

At-speed patterns passed timing but failed in production due to peak shift IR; staggered capture and power-aware fill resolved.

Debug branches

  • Tag test and functional corners separately

  • Check hold in shift mode

  • Correlate fail bins with power hotspots

Senior review question

Ask: what evidence proves this DFT decision is safe for production?

Key takeaways

  • State metric, lot/corner context, and pattern tag with every claim.

  • Treat timing, power, and quality as one signoff problem.

Common pitfalls

  • Chasing coverage without legality checks.

  • Ignoring test-power side effects of pattern changes.

  • Debugging silicon without reproducible tags.

Principal DFT review addendum

Shift mode is hold-sensitive while capture mode is setup-sensitive; closure must preserve both under test clocking assumptions.

Metric: shift hold violations, capture setup failures, at-speed pattern pass rate